Effect of the Horizontal Perforated Plates on the Turbidity Removal Efficiency in Water Treatment Plant of Tikrit University

Main Article Content

Ahmed Khaleel Ibrahim

Abstract

The study aims to show effect of adding the circular perforated plates in sedimentation basin in horizontal position on the efficiency of the sedimentation basin as was the use of perforated panels with circular holes and placed inside the sedimentation basin and took two levels of turbidity of the water 125 and 150 NTU respectively in the Tigris river during the preparation of the study with variable hydraulic load and the efficiency was calculated at each case of plates in the basin where the variables that were adopted is the number of perforated panels so that the ratio of the area of holes/total area of panel is 20% , and also variation in water turbidity levels and the hydraulic load. The result showed a significant decrease in the output turbidity levels from sedimentation tank with the use of perforated panels at the raw water turbidity 150 NTU and hydraulic load between 0.9 and 1.2 m3/m2.hr were 95% higher efficiency when three panels were put and hydraulic load 0,9 m3/m2.hr, while there was fluctuation with some of hydraulic load levels at turbidity level of 125 NTU and same number of panels.

Metrics

Metrics Loading ...

Article Details

Section
Articles

Plaudit

References

سماكة، اسراء سعدي عبد الأمير. قيا الكدرة لتقييم كفاءة [

الشب في محطات تصفية مياه الشرب في محافظة بابل.

رسالة ماجستير، كلية الهندسة/ جامعة بابل، 2005

[ 2 عبد الرزاق، ايمان عبد الرحمن. دراسة مقارنة لعمل الالواح [

المثقبة في حوض الترسيب. المؤتمر العلمي الدوري الثاني

لمركز بحوث البيئة والسيطرة على التلوث 2011

Price FA, Yonge DR. Enhancing contaminant removal in stormwater detention basins by coagulation. Transportation research record. 1995;1483:105-111.

Wang. X.R, Pan LD, Zhang, HX, Sun, H-L Dal, HL, Christiana DC. "Follow-up study

of Water treatment plants insane Diago". J. AWWA, Sep. PP 480-483.

Knappe D, Briley O, Rastogi N. Strategies for algae removal in conventional treatment. American Water Works Association-Annual Conference 1998; Dallas, USA.

Petrusevski Bv, Van Breemen A, Alaerts G. Effect of permanganate pre-treatment and coagulation with dual coagulants on algae removal in direct filtration. Aqua. 1996;45:316-326.

Jun H-B, Lee Y-J, Lee B-D, Knappe DR. Effectiveness of coagulants and coagulant aids for the removal of filter-clogging Synedra. Journal of Water Supply: Research and Technology-AQUA. 2001;50:135-148.

Fun. Colloid and surfaces Aphyieochem. Eng Aspects, 162,141- 148.

Similar Articles

You may also start an advanced similarity search for this article.