The Impact of Width of the Air Gap Channel on the Mass Flow Rate, Rayleigh Number, and Efficiency of Passive Solar Heating System
Main Article Content
Abstract
The mass flow rate and Rayleigh number has been investigated experimentally on the passive solar using Trombe wall consist of (industrial wax) used as phase change material (PCM). A test rig of a cubicle was made of PVC sandwich panel except the south wall, Trombe wall; covered with a clear glass of 6 mm thickness. The six experiments were carried out during the winter season in Kirkuk city with six different widths of the air gap channel (10, 15, 20, 25, 30, and 35) cm. The experimental resultts show that the mass flow rate proportional directly to a width of the channel and inversely with Rayleigh number. Moreover, the highest efficiency was obtained at a depth of 30 cm, where it was about 2.45 times the efficiency of 10 cm.
Metrics
Article Details

This work is licensed under a Creative Commons Attribution 4.0 International License.
THIS IS AN OPEN ACCESS ARTICLE UNDER THE CC BY LICENSE http://creativecommons.org/licenses/by/4.0/
Plaudit
References
Mazria E. Passive solar energy book; 1979.
Duffie JA, Beckman WA. Solar engineering of thermal processes: John Wiley & Sons; 2013. DOI: https://doi.org/10.1002/9781118671603
Williams RJ. Passive solar heating. Ahn Arbor Science; 1983.
Akbari H, Borgers T. Free convective laminar flow within the Trombe wall channel. California Univers-ity, Berkeley (USA). Lawrence Berkeley Lab.; 1978: pp 165-174. DOI: https://doi.org/10.1016/0038-092X(79)90101-4
Akbarzadeh A, Charters W, Lesslie D. Thermocir-culation characteristics of a Trombe wall passive test cell. Solar Energy 1982; 28 (6): 461-468. DOI: https://doi.org/10.1016/0038-092X(82)90317-6
Borgers T. Free convective turbulent flow within the trombe wall channel. 1979: pp. 253-264. DOI: https://doi.org/10.1016/0038-092X(84)90156-7
Koczyk H, Górka A. Numerical investigations of heat transient in a Trombe's wall. Statyba 1996; 2: 73-79. DOI: https://doi.org/10.1080/13921525.1996.10531647
Chen B, Zhao J, Chen C, Zhuang Z. Experimental investigation of natural convection in Trombe wall systems. Envelope Technologies for Building Energy Efficiency 2006; II: 1-5.
El-Ghnam RI. Numerical investigation of natural convection heat transfer between two vertical plates with symmetric heating. International Journal of Thermal Technologies 2015; 5 (1): 31-44.
Khalifa A, Abbas E. The optimum thickness of some thermal storage materials used for solar space heating. World Renewable Energy Congress VIII (WREC); 2004.
Okpani P. Investigation of the effect of the thermal wall thickness on its back surface temperature for a poultry brooding pen heated by Trombe wall; 2013.
Faris SS, Chaichan MT, Sachit MF, Jaleel JM. Simulation and numerical investigation of effect air gap thickness on Trombe wall system. International Journal of Application or Innovation in Engineering & Management 2014; 3 (11): 159-168.
Su Y, Zhao B, Lei F, Deng W. Numerical modelling of effect of channel width on heat transfer and ventilation in a built-in PV-Trombe wall. Journal of Physics 2016; 745 pp. 9. DOI: https://doi.org/10.1088/1742-6596/745/3/032069
Hu H, Argyropoulos SA. Mathematical modelling of solidification and melting: a review. Modelling and Simulation in Materials Science and Engineering 1996; 4 (4): 371. DOI: https://doi.org/10.1088/0965-0393/4/4/004
Onbasioglu H, Egrican AN. Experimental approach to the thermal response of passive systems. EnergyConversion and Management 2002; 43 (15): 2053-2065. DOI: https://doi.org/10.1016/S0196-8904(01)00138-8
Shashikant KN. Numerical analysis of house with Trombe wall. International research Journal of Engineering and Technology 2016; 3: 4-8.
Alzaed AN. Experimental investigation on performance of trombe wall passive solar technique for buildings cooling in arid regions. International Journal of Innovative Research in Science, Engineering and Technology 2016; 5: 9-17.
Ruiz Á, Salmerón J, González R, Álvarez S. A calculation model for Trombe walls and its use as a passive cooling. Proceedings of International Conference Passive and Low Energy Cooling for the Built Environment, Santorini, Greece; 2005. pp. 365-369.
Chen B, Chen X, Ding Y, Jia X. Shading effects on the winter thermal performance of the Trombe wall air gap: An experimental study in Dalian. Renewable Energy 2006; 31 (12): 1961-1971. DOI: https://doi.org/10.1016/j.renene.2005.07.014
Heim D, Clarke JA. Numerical modelling and thermal simulation of PCM–gypsum composites with ESP-r. Energy and Buildings 2004; 36 (8): 795-805. DOI: https://doi.org/10.1016/j.enbuild.2004.01.004
Chaichan MT, Abass KI, Jawad RS, Mahdy AM. Thermal performance enhancement of simple Trom-be wall. International Journal of Computation and Applied Sciences 2017; 2 (1): 33-40. DOI: https://doi.org/10.24842/1611/0022
Burek S, Habeb A. Air flow and thermal efficiency characteristics in solar chimneys and Trombe Walls. Energy and Buildings 2007; 39 (2): 128-135. DOI: https://doi.org/10.1016/j.enbuild.2006.04.015
Karmare S, Tikekar A. Analysis of fluid flow and heat transfer in a rib grit roughened surface solar air heater using CFD. Solar Energy 2010; 84 (3): 409-417. DOI: https://doi.org/10.1016/j.solener.2009.12.011
Mawlood MK Abbas EF. Simulation of velocity and temperature fields in a Trombe wall system. Al-Rafadain Engineering Journal 2014; 22:. DOI: https://doi.org/10.33899/rengj.2014.87340
Abbas EF. Study the effect of glass layers on the thermal performance of Trombe wall. Tikrit Journal of Engineering Sciences 2006; 13: 20. DOI: https://doi.org/10.25130/tjes.13.3.08
Koyunbaba BK, Yilmaz Z. The comparison of Trombe wall systems with single glass, double glass and PV panels. Renewable Energy 2012; 45: 111-118. DOI: https://doi.org/10.1016/j.renene.2012.02.026
Kurnuç A, Kara YA. Energy evaluation of a phase change material wall covered with novel triple glass. ISI Bilimi ve Teknigi Dergisi/Journal of Thermal Science & Technology 2014; 34 (1):.
Khalifa AJN, Abbas EF. A comparative performance study of some thermal storage materials used for solar space heating. Energy and Buildings 2009; 41 (4): 407-415. DOI: https://doi.org/10.1016/j.enbuild.2008.11.005
Kamal V, Mishra R. Computer Simulation of Trombe Wall for Porous and Non-Porous Strutcures. International Journal 2014; 2 (1): 151-165.
Castell A, Martorell I, Medrano M, Pérez G, Cabeza LF. Experimental study of using PCM in brick constructive solutions for passive cooling. Energy and Buildings 2010; 42 (4): 534-540. DOI: https://doi.org/10.1016/j.enbuild.2009.10.022
Pasupathy AP, Velraj R. Mathematical modeling and experimental study on building ceiling using phase change material for energy conservation. sustainable energy and environment (SEE 2006), 21-23 Novem-ber 2006, Bangkok, Thailand. DOI: https://doi.org/10.1115/IMECE2006-14686
Hassan KAA, Alnoman H, Rashid Y, Abdelbaqi S. Phase change materials (PCMS) integrated into concrete blocks to recduced cooling load in hot claimatic. ZEMCH International Conference, Malaysia; 23 December, 2016: pp. 270-278.
Fortunato B, Camporeale S, Torresi M, Albano M. Simple mathematical model of a thermal storage with PCM. AASRI Procedia 2012; 2: 241-248. DOI: https://doi.org/10.1016/j.aasri.2012.09.041
Holman JP. Heat transfer. 10th ed. New York;The McGraw Hill Companies: 2010.